Temporal Gain Variations in Time-Division Multiplexed Raman Pumping Schemes
01 January 2002
We show that time-division multiplexed Raman pumping, previously proposed to remove pump-to-pump interactions, must have a minimum pump pulse repetition rate of 100 kHz to achieve temporal gain variations of less than 0.3 dB at 15 dB average gain.